The IBLWP Batch Controller is an universally AC or 12-40VDC powered batch controller for liquids that incorporates a six (6) digit 18mm backlit LCD (liquid crystal display). The instrument can be configured for dual stage batching and can function in batch up or down. The IBLWP provides the excitation power supply for the flow sensor.
Make an enquiryThe instrument can be configured to batch volumes from 0.001 to 999,999 litres. The IBL can operate in local manual mode by front panel touch switches for Batch Start, Stop & resume or in remote mode as these functions are available for external control.
The instrument accepts an input from 0 to 2KHZ and is dip switch selectable for open collector, reed, Hall, Namur and turbine signals (from 20mV peak to peak).
Input Type |
sw1 |
sw2 |
sw3 |
sw4 |
Sw5 |
sw6 |
sw7 |
sw8 |
|
A |
CMOS Logic Level |
Off |
Off |
Off |
Off |
On |
Off |
Off |
off |
B |
Open collector or reed switch |
Off |
Off |
Off |
Off |
On |
Off |
On |
off |
C |
Namur proximity [loop supply 8VDC] |
Off |
Off |
On |
On |
On |
Off |
Off |
off |
D |
Reed switch with debounce |
Off |
Off |
Off |
Off |
On |
Off |
On |
On |
E |
Coil 50mV PP minimum |
Off |
On |
Off |
Off |
Off |
Off |
Off |
off |
F |
Low impedance coil 50mV PP min. |
On |
On |
Off |
Off |
Off |
Off |
Off |
off |
The IBW incorporates a six (6) digit 18mm digit height (LCD) display with integrated white LED backlight with a wide viewing angle and a viewing distance of 5 metres. The front panel switched are an embossed membrane type with positive action.
The instrument incorporates a Bluetooth interface to an App and Tablet or drive a ticket printer with client header, batch total, accumulated total, current time, current date and batch number.
The instrument incorporates a background running total that is stored in eeprom memory during loss of power. This total can be displayed by the front total touch button and reset.
The instrument has a low flow alarm. If no pulses are received in a pre- programmed period the alarm is activated, the batch is cancelled and LF ERR is displayed.
Terminal 1: Input Common (-) |
Terminal 11: 4-20mA Output 2 |
Terminal 2: Input minus 1 (-) |
Terminal 12: Low flow alarm open collector output |
Terminal 3: Input plus 1 (+) |
Terminal 13: Relay one normally open contact |
Terminal 4: Input minus 2 (-) |
Terminal 14: Relay one common contact |
Terminal 5: Input Plus 2 |
Terminal 15: Relay two normally open contact |
Terminal 6: 8 to 24VDC loop Supply |
Terminal 16 Relay two common contact |
Terminal 7: Reset |
Terminal 17: Ground Supply |
Terminal 8: Start |
Terminal 18: 85 to 265VAC/24VDC active supply |
Terminal 9: Stop |
Terminal 19: VAC Neutral /0VDC common supply |
Terminal 10: 4-20mA Output 1 |
Terminal 20: Not used |
Fig.1 Batcher function diagram
Four membrane switches on the front panel allow the batch quantity to be set and batching operations to be started, stopped, resumed and reset. When the batcher is running the DISPLAY button can be used to show the background total and the Batch Set button to change the batch quantity.
The instrument has a universal AC power supply that allows it to be powered from 85 to 265VAC and 47 to 63 Hz. Alternatively it can be supplied as a DC powered instrument that operate from 12 to 40VDC.
Two output relays are provided for single or dual stage valve control. Relay one will energise at the start of the batch and de-energise at the end of batch. Relay two will energise at a programmed delay after batch start and de-energise at a programmed quantity prior to completion of the batch. This function allows a slow start and slow shutdown of the batch operation.